  • Line Life Cardiovascular

    About Us Interventional Cardiology Interventional Radiology Radiofrequency Ablation Hemostats Endovascular Accessories Be a Distributor Blog Resultados de busca More Catalog Download ↓ Download Scientific Study ↓ Guidewire Control Catheter with Deflectable Tip The Venture is a unique single-lumen catheter with a distal tip that can be deflected up to 90° using a distal handle. It has a high capacity to direct, guide and control 0.014” guidewires, providing high support during complex percutaneous and CTO interventions performed in the coronary and peripheral arterial system. Available in OTW and RX system. OTW versions also provide manual and selective administration of diagnostic and therapeutic agents. ​ When to use Venture? Tortuous and angled anatomy Bifurcations side branches Branches entrapped by stent Features and Benefits ​ Deflectable Tip ​ Catheter tip deflectable up to 90°; 8 mm platinum tip for excellent visibility under fluoroscopy. ​ Excellent Torque Response ​ Shaft designed with multiple spiral layers providing high transmission of torque from the proximal end to the tip. ​ Exclusive Support ​ Tip angulation provides precise support for accessing difficult and highly complex lesions. ​ Traceability ​ Flexible, low-profile tip; Surface with hydrophilic coating offering high performance and excellent navigability in tight and tortuous anatomies. Quick Change Model Deflector Button Ponta Hipotube Over-The-Wide Model (OTW) Handle Torque Transmitter hub ANVISA REGISTRATION No.: 10332340177 Interventional Cardiology Interventional Radiology Vascular and Endovascular Accessories Hemostatics

  • Line Life Cardiovascular

    About Us Interventional Cardiology Interventional Radiology Radiofrequency Ablation Hemostats Endovascular Accessories Be a Distributor Blog Resultados de busca More Catalog Download ↓ Galt Medical is a leading manufacturer of 0.018” micro-access products. The Fluent™ No-Transition MicroIntroducer is designed to facilitate percutaneous micro-access, with redesigned angles and silicone coating. Tests show that Fluent™ is the most effective micro-introducer in its class at reducing penetration force. ​ Main features: Fluent transition; Diameters of 4Fr and 5Fr; X-Sharp® 21 GA echogenic needle extra sharp with bevel indicator; Variety of guide options including highly radiopaque tips; Available in complete kits. ANVISA REGISTRATION: 10350530185 Interventional Cardiology Radiologia Intervencionista Vascular and Endovascular Accessories Hemostatics

  • Line Life Cardiovascular

    Connection Tube for High Pressure Injection Home Company Products Contact us The connection tube for high pressure injection is an accessory widely used to direct fluids in hemodynamic procedures. Characteristics ​ Resistant material; Able to withstand pressures of up to 1200 psi; Available up to 76 and 120 cm in length. For more information, please contact our commercial sector. Phone: +55 11 3847-1100 - E-mail: comercial@linelife.com Interventional Cardiology Interventional Radiology Vascular and Endovascular Accessories Biopsy

  • Line Life | Importadora de produtos médicos hospitalares | Alameda dos Tupinás, 33 - 4º andar, conj. 408 - Planalto Paulista, São Paulo - SP, Brasil

    100% Welcome to Line Life Since 1996, Line Life Cardiovascular has been Importing and Distributing Hospital Medical Products for Interventional Cardiology, Interventional Radiology, Radiofrequency Ablation and General Surgery segments. Headquartered in São Paulo, Line Life is present throughout the national territory by Representatives and Distributors. About Us Discover Our Products Interventional Cardiology Interventional Radiology Radiofrequency Ablation of Nodules and Tumors Hemostats A bsorbable Accessories Institutional presentation

  • Line Life Cardiovascular

    manifold Home Company Products Contact us Manifold is an accessory that controls the fluid flow and monitors the pressure used in hemodynamic diagnostic and therapeutic procedures. This is a multi-port device: it has 3 stopcocks with outputs direction to the right and a total of 5 high-pressure ways able to support up to 500 psi and luer lock edges. It presents a large inner lumen of 2.3 mm diameter – combining the high pressure capability with the capability of high flow direction. For more information, please contact our commercial sector. Phone: +55 11 3847-1100 - E-mail: comercial@linelife.com Interventional Cardiology Accessories Interventional Radiology Vascular and Endovascular Biopsy

  • Line Life Cardiovascular

    CASE STUDY PAPER PRESENTED AT THE CONGRESS SOBRICE 2015 USE OF HIGH CALIBER DRAINS - URESIL Title: PERCUTANEOUS DRAINAGE OF NECROHEMORRHA PANCREATITIS GICA: REPORT OF TWO CASES Theme: non-vascular interventions Authors: Renan Rocha da Nobrega; Marcela Pecora Cohen; Ricardo Miguel Costa de Freitas; Ricardo Miguel Costa de Freitas; Institution: INSTITUTE OF RADIOLOGY OF THE HOSPITAL DAS CLINICS FM-USP Summary: Goal: to describe the case of two patients with necrohemorrhagic pancreatitis treated exclusively with antimicrobials and image-guided percutaneous drainage. Case reports: (Case #1) male patient, 56 years old, admitted with epigastric pain, nausea, amylase 3,633 mg/dL, C-reactive protein (CRP) 37.8 mg/dL, leukocytosis (15,700/mm3) and edematous pancreatitis of biliary etiology on CT scan computerized (CT) – classification of severity according to the Balthazar criteria moderate upon admission and severe after 10 days. He evolved with multiple retroperitoneal collections, being submitted to percutaneous drainage of the collections guided by CT and fluoroscopy with five large caliber drainage catheters (16 to 28F) and serial washing of the drains in the following four weeks. The patient was discharged after clinical and laboratory improvement and resolution of the collections; (Case #2) female patient, 36 years old, admitted with abdominal pain and distention; amylase 1,378 mg/dL, CRP 37.8 mg/dL, leukocytosis (12,400/mm3), LDH 1,966 mg/dL, hypertriglyceridemia and CT signs of severe necrotizing pancreatitis (Balthazar criteria). After three days of hospitalization, we opted for percutaneous drainage of retroperitoneal collections with seven large-caliber drains and antibiotic therapy, with progressive clinical and laboratory improvement, removal of the drains in 30 days, followed by hospital discharge. Discussion: necrohemorrhagic pancreatitis represents the most serious complication of acute pancreatitis. Mortality rates vary between 30 and 50% and have been improving with advances in surgical and clinical care. Surgical necrosectomy has been the standard treatment, but percutaneous drainage has been the treatment option in some patients, with variable success rates. The indication of the percutaneous approach for NIBP remains controversial and the severity criteria (Ranson, Balthazar) seem to be relevant in the therapeutic decision. See the list of papers approved by Congress at the link: http://www.sobrice2015.com.br/SOBRICE%20-%20trabalhos%20aprovados.pdf Interventional Cardiology Interventional Radiology Vascular and Endovascular Accessories Hemostatics

  • Line Life Cardiovascular

    Radial Artery Compression Tourniquet Home Company Products Contact us Radial Artery Compression Tourniquet (RACT) that provides full control over inflation and deflation, offering the perfect balance between a safe hemostasis and patient's comfort. The Double Safety Lock provides a perfect balance of safe hemostasis and patient comfort; ​ The Luer lock prevents air leakage and makes operation easier and safer; ​ Our proprietary 2ml controlled air release lock design allows for a precise and step-wise deflation resulting in a safer and more comfortable hemostasis for patients; ​ Velcro strip to host the inflation syringe in place; ​ Clear visualization through balloon allows for easy control of hemostatic process. For more information, please contact our commercial sector. Phone: +55 11 3847-1100 - E-mail: comercial@linelife.com Interventional Cardiology Interventional Radiology Vascular and Endovascular Accessories Biopsy

  • Line Life Cardiovascular

    Download Brochure ↓ Home Company Products Contact us The Best Guide Catheter Guide catheter developed with superior features and technology that provides an accurate and atraumatic delivery in the target vessel. Key Features: ​ ​ Low resistance due to the unique hydrophilic coating Smooth catheter introduction; Less traumatic to the vessel wall. Low friction during navigability in tortuous calcified anatomies; Spasms reduced during steerability in procedures via the radial artery, resulting in greater comfort to the patient. ​ Best torque response Braided and encapsulated layer of flat wire, ultra-thin and resistant, which ensures a high resistance to kink during procedures performed via radial approach and excellent steerability and response to torque; Navigability free from friction with real control of the tip and torque. ​ Excellent support Excellent maintenance of the shape of the catheter, even after prolonged procedure time; Excellent flexibility even at minimum temperatures; Uncoated tip providing excellent grip and support. Eg: ostia. ​ Larger inner lumen and smaller outer diameter Inner and outer diameter dimensions greater than the competition's; Larger inner diameter and smaller outer diameter. ANVISA REGISTRATION: 10350530144 Interventional Cardiology Interventional Radiology Vascular and Endovascular Accessories Biopsy

  • Line Life Cardiovascular

    Extension Catheter - GuideLiner Catalog Download ↓ Download the Clinical Case ↓ The only extension catheter to guide catheter capable of combining quick change system convenience with unrivaled distal range. GuideLiner is a highly flexible, kink-resistant, atraumatic, and excellently navigable guide catheter extension catheter that allows for perfect coaxial alignment and deeper, more distal positioning, aiding in the delivery of balloons and stents, as well as providing selectivity in the infusion of diagnostic and therapeutic agents during interventional procedures in tortuous arteries. ​ Main features: ​ Perfect coaxial alignment of the guiding catheter High steering capability for accessing distal vessels Excellent support for percutaneous treatment of highly calcified lesions or chronic total occlusions in tortuous anatomies Exclusive technology that allows the protection of the previously implanted proximal stent, during the perfect implantation of a distal stent Selective delivery of contrast in distal portions Made of stainless steel, with an internal PTFE coating and surrounded by an external layer of Pebax Quick-change lumen 25 cm long and 20 cm long for guide catheter (yellow distal portion) Compatible with 6F guide catheter and 0.014” guide wire ​ ​ ​ ​ ​ ANVISA REGISTRATION No: 10350530066

  • Line Life Cardiovascular

    Biotech Angiographic Catheters Download Brochure ↓ Home Company Products Contact us A Great Option For High Quality Images The Biotech angiographic catheters provides excellent flow rates, optimal contrast medium delivery vessel opacification. ​ ​ ​ ​ Features and Benefits: ​ Curves suitable for performing coronary, peripheral, and cerebral imaging; Shaft designed in braided nylon for applications that require high torque, burst pressure resistance, pushability, steerability and kink resistance due to its double mesh. Proximal segment in non braided nylon for maximum flexibility and maintain its shape; Soft, radiopaque nylon tip for minimal vessel trauma; Large than standard inner allows higher flow rate with less resistance; Maximum recommended injection pressure: 1200 psi; Recommended max guidewires at 0.038”. ANVISA REGISTRATION: 10350530114 Interventional Cardiology Interventional Radiology Vascular and Endovascular Accessories Hemostatics

  • Line Life Cardiovascular

    Star Electrode Predictable, reliable and economical electrode. Characteristics: ​ Internally cooled electrode designed with a small, lightweight handle Sharp needle tip allows for easy percutaneous approach with positive user feedback Precise ablation to the targeted superficial lesion in a critical area using 18G ​ ​ REGISTRO ANVISA No.: 10350530222

  • Line Life Cardiovascular

    Download Brochure ↓ Home Company Products Contact us A diagnostic catheter developed by PendraCare with the highest technology, capable of providing superior quality and features, as well as a smooth delivery, precise, atraumatic and totally reliable in tortuous anatomies and calcified lesions, providing an ideal torque control during handling in the coronary arteries. Key Features: Low resistance due to the unique hydrophilic coating Smooth catheter insertion; Atraumatic to the vessel wall; Unique surface pattern that results in low friction during navigability in the coronary arteries. ​ The largest inner lumen in the market Inner diameter larger than the competition's; Largest inner lumen diameter, enabling its complete filling with contrast to a perfect radiopacity of the vessel. ​ Far superior kink resistance ​ Double braided stainless steel layer, providing high kink resistance in addition to a perfect torque transfer from the proximal portion to the distal portion of the catheter; Bends with diameters lower than 2.5 cm, making it the ideal catheter for radial procedures. ​ Atraumatic and soft tip Totally atraumatic and soft tip, ensuring a smooth and easy introduction, reducing the likelihood of damage and dissections in the vessels. ANVISA REGISTRATION: 10350530145 Interventional Cardiology Interventional Radiology Accessories Vascular and Endovascular Biopsy